{"id":2338,"date":"2025-10-31T02:02:32","date_gmt":"2025-10-31T02:02:32","guid":{"rendered":"https:\/\/andely.us\/?post_type=succes-stories&#038;p=2338"},"modified":"2025-10-31T02:02:32","modified_gmt":"2025-10-31T02:02:32","slug":"how-we-helped-a-plastic-injection-plant-cut-90-of-its-energy-consumption","status":"publish","type":"succes-stories","link":"https:\/\/andely.us\/?succes-stories=how-we-helped-a-plastic-injection-plant-cut-90-of-its-energy-consumption","title":{"rendered":"How We Helped a Plastic Injection Plant Cut 90% of Its Energy Consumption"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\" id=\"block-ffafe34f-2a6e-4fe0-a7cb-267bfe2d1cf9\"><strong>$87,389 per year. <\/strong>That\u2019s how much a plastic injection molding plant is saving after optimizing its cooling system with a customized solution designed and implemented by <strong>Andely Solutions<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"block-00e9f5d1-d295-4828-a03d-999dfcef2319\">This project reduced <strong>90.5%<\/strong> of the energy used for hydraulic equipment cooling, extended hydraulic oil life, lowered maintenance costs, and improved overall production efficiency.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"block-66837715-760b-4362-9fa0-3d1e8df19890\">Here\u2019s how we achieved it.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"block-ef301ad7-a1d5-47d3-a07e-70205b28f2ae\"><strong>The Cooling Challenge in the Plastics Industry<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"block-df1bcd24-7747-4c9f-8030-f97cec3bec06\">If you run a plastic injection facility, you know that cooling is critical to maintaining process stability and productivity. Yet, in many plants, cooling systems often create more problems than they solve.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"block-5b7d43e5-d137-43da-888e-123bbb4e8214\">Typical challenges include:<\/p>\n\n\n\n<ul id=\"block-97837b17-0779-4e43-bdd0-e3ba38c695d1\" class=\"wp-block-list\">\n<li>Scale buildup and contamination in water circuits<\/li>\n\n\n\n<li>Frequent hydraulic system failures<\/li>\n\n\n\n<li>High energy consumption<\/li>\n\n\n\n<li>Reduced oil life due to inefficient cooling<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"block-51092e73-d0db-4369-9ca7-8c658599a602\">In markets where electricity costs continue to rise \u2014 especially during hot months \u2014 these inefficiencies directly impact profitability and production continuity.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"block-f3541c17-820b-4e2a-bcc0-4c69c1d9e616\"><strong>Diagnosis: What We Found<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"block-8b5b5692-244a-4d9c-8148-73da34d17c06\">After a detailed on-site assessment, our engineering team identified two major issues:<\/p>\n\n\n\n<ol id=\"block-5ad2a1e4-0125-4b0a-aa0a-628da09c704f\" class=\"wp-block-list\">\n<li><strong>Low energy efficiency:<\/strong><strong><br><\/strong>The plant relied on a single mechanical chiller to cool both molds and hydraulic systems, overloading its capacity and driving up consumption.<br><\/li>\n\n\n\n<li><strong>Excessive power use:<\/strong><strong><br><\/strong>The hydraulic cooling circuit alone required <strong>860,932.80 kWh per year<\/strong>, representing one of the plant\u2019s highest operational expenses.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"block-7d1c7d69-e477-4608-9f77-ad364af4313b\"><strong>Our Solution<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"block-2be962d1-a843-4350-a558-650a784e9979\">The Andely engineering team proposed a simple yet highly effective strategy: <strong>split the cooling system into two independent circuits<\/strong> for improved control and energy efficiency.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"block-b4e838f5-fa11-4df3-8e25-b9267b9f8b60\">Here\u2019s what we implemented:<br>\ufeff<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"block-750366c7-7002-46dd-89b7-d50713ae03a6\">\u2705 <strong>Eco Cool Water system (adiabatic dry cooler)<\/strong> dedicated exclusively to hydraulic circuit cooling.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"block-ca60bd2e-8e8c-4b92-a073-74325971051c\">\u2705 <strong>Reassignment of the existing chiller<\/strong> to handle mold cooling only.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"block-4e87eebe-989e-40d4-aeac-c48433c3cafa\">\u2705 <strong>Full redesign of the hydraulic distribution system<\/strong> to eliminate leaks, pressure losses, and inefficiencies.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"block-71177dc2-85a0-4842-a19b-49ebcef9d303\">The full installation was completed in about <strong>four months<\/strong>, including the setup of a dedicated area for the adiabatic system.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"block-87c6d2ec-4e85-4515-87d8-2a1b84c355e5\"><strong>Results: 90.5% Less Energy Consumption<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"block-85b24976-9b2e-4923-87a3-fb010fa86d9d\">The results were immediate and measurable:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Metric<\/strong><\/td><td><strong>Chiller&nbsp;<\/strong><\/td><td><strong>Eco Cool Water<\/strong><\/td><\/tr><tr><td>Power consumption (kW\/h)<\/td><td>92.28<\/td><td>&#8211;&nbsp;<\/td><\/tr><tr><td>Annual consumption (kWh\/year)<\/td><td>860,932.80<\/td><td>75,405.82<\/td><\/tr><tr><td>Annual electricity cost (USD)<\/td><td>95,778.78<\/td><td>8,388.89<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"block-6386242f-3ea2-4d85-b2fd-b3a4b69d2101\"><strong>Total savings: $87,389 USD\/year<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"block-16b7b446-c3b7-496e-b45b-c8fa02381175\">Other key benefits:<\/p>\n\n\n\n<ul id=\"block-67ae9669-8c4e-4da5-9b8f-79eb3b669015\" class=\"wp-block-list\">\n<li>Extended hydraulic oil life thanks to stable temperature control<\/li>\n\n\n\n<li>Improved process reliability and uptime<\/li>\n\n\n\n<li>Lower maintenance costs and reduced downtime<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"block-ca543fdf-c65a-447b-a32f-1fb5a80bc7e6\"><strong>Why This Strategy Works<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"block-4d449c10-ecce-45a3-ae8a-3371b69e183d\">Separating the cooling circuits allows each system to run under optimal conditions while using the most efficient technology for its purpose.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"block-50a6a9cc-4899-4fad-b5f5-1f0ca83d95dc\"><strong>Andely\u2019s Eco Cool Water systems:<\/strong><\/p>\n\n\n\n<ul id=\"block-cb0487a3-5927-4d56-ba2b-d81c08c6dcfa\" class=\"wp-block-list\">\n<li>Operate without refrigerant gases or compressors<\/li>\n\n\n\n<li>Use adiabatic pre-cooling only when necessary, maximizing water and energy savings<\/li>\n\n\n\n<li>Eliminate biological risks like <em>Legionella<\/em>, common in open cooling towers<\/li>\n\n\n\n<li>Require minimal maintenance and ensure long-term durability<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"block-96ea7eb8-fe1e-4a0b-aa32-f3890365b498\"><strong>Can Your Plant Achieve Similar Results?<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"block-dea12bf3-1786-4b8e-83f4-b56a0b98a9eb\">Absolutely. This approach can be applied to <strong>any manufacturing facility<\/strong> that currently relies on chillers or cooling towers for process cooling.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"block-e1c1352d-762d-45a8-87fd-7cabdf562918\">At <strong>Andely Solutions<\/strong>, we help industrial clients:<\/p>\n\n\n\n<ul id=\"block-2b41b841-7b39-4bee-946e-776950df79ec\" class=\"wp-block-list\">\n<li>Reduce water and energy costs<\/li>\n\n\n\n<li>Optimize thermal processes<\/li>\n\n\n\n<li>Transition to sustainable HVAC-R systems<\/li>\n\n\n\n<li>Boost productivity and reliability across operations<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\" id=\"block-7cf2a76d-2f31-4e4b-a6aa-4e7079553c49\">Interested in learning how much your facility could save?&nbsp; \ud83d\udc49 <strong>Request a free assessment<\/strong> or explore our <strong>Eco Cool Water<\/strong>, <strong>Turbocor chiller<\/strong>, and <strong>plastic injection cooling solutions<\/strong> to discover how we can help you modernize your plant\u2019s cooling performance.<\/p>\n","protected":false},"featured_media":2282,"template":"","meta":{"_acf_changed":false},"class_list":["post-2338","succes-stories","type-succes-stories","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>How We Helped a Plastic Injection Plant Cut 90% of Its Energy Consumption - Andely<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/andely.us\/?succes-stories=how-we-helped-a-plastic-injection-plant-cut-90-of-its-energy-consumption\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How We Helped a Plastic Injection Plant Cut 90% of Its Energy Consumption - Andely\" \/>\n<meta property=\"og:description\" content=\"$87,389 per year. That\u2019s how much a plastic injection molding plant is saving after optimizing its cooling system with a customized solution designed and implemented by Andely Solutions. This project reduced 90.5% of the energy used for hydraulic equipment cooling, extended hydraulic oil life, lowered maintenance costs, and improved overall production efficiency. Here\u2019s how we [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/andely.us\/?succes-stories=how-we-helped-a-plastic-injection-plant-cut-90-of-its-energy-consumption\" \/>\n<meta property=\"og:site_name\" content=\"Andely\" \/>\n<meta property=\"og:image\" content=\"https:\/\/andely.us\/wp-content\/uploads\/2025\/10\/How-We-Helped-a-Plastic-Injection-Plant-Cut-90.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1300\" \/>\n\t<meta property=\"og:image:height\" content=\"860\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/andely.us\\\/?succes-stories=how-we-helped-a-plastic-injection-plant-cut-90-of-its-energy-consumption\",\"url\":\"https:\\\/\\\/andely.us\\\/?succes-stories=how-we-helped-a-plastic-injection-plant-cut-90-of-its-energy-consumption\",\"name\":\"How We Helped a Plastic Injection Plant Cut 90% of Its Energy Consumption - Andely\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/andely.us\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/andely.us\\\/?succes-stories=how-we-helped-a-plastic-injection-plant-cut-90-of-its-energy-consumption#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/andely.us\\\/?succes-stories=how-we-helped-a-plastic-injection-plant-cut-90-of-its-energy-consumption#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/andely.us\\\/wp-content\\\/uploads\\\/2025\\\/10\\\/How-We-Helped-a-Plastic-Injection-Plant-Cut-90.webp\",\"datePublished\":\"2025-10-31T02:02:32+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/andely.us\\\/?succes-stories=how-we-helped-a-plastic-injection-plant-cut-90-of-its-energy-consumption#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/andely.us\\\/?succes-stories=how-we-helped-a-plastic-injection-plant-cut-90-of-its-energy-consumption\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/andely.us\\\/?succes-stories=how-we-helped-a-plastic-injection-plant-cut-90-of-its-energy-consumption#primaryimage\",\"url\":\"https:\\\/\\\/andely.us\\\/wp-content\\\/uploads\\\/2025\\\/10\\\/How-We-Helped-a-Plastic-Injection-Plant-Cut-90.webp\",\"contentUrl\":\"https:\\\/\\\/andely.us\\\/wp-content\\\/uploads\\\/2025\\\/10\\\/How-We-Helped-a-Plastic-Injection-Plant-Cut-90.webp\",\"width\":1300,\"height\":860},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/andely.us\\\/?succes-stories=how-we-helped-a-plastic-injection-plant-cut-90-of-its-energy-consumption#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/andely.us\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How We Helped a Plastic Injection Plant Cut 90% of Its Energy Consumption\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/andely.us\\\/#website\",\"url\":\"https:\\\/\\\/andely.us\\\/\",\"name\":\"Andely\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/andely.us\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How We Helped a Plastic Injection Plant Cut 90% of Its Energy Consumption - Andely","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/andely.us\/?succes-stories=how-we-helped-a-plastic-injection-plant-cut-90-of-its-energy-consumption","og_locale":"en_US","og_type":"article","og_title":"How We Helped a Plastic Injection Plant Cut 90% of Its Energy Consumption - Andely","og_description":"$87,389 per year. That\u2019s how much a plastic injection molding plant is saving after optimizing its cooling system with a customized solution designed and implemented by Andely Solutions. This project reduced 90.5% of the energy used for hydraulic equipment cooling, extended hydraulic oil life, lowered maintenance costs, and improved overall production efficiency. Here\u2019s how we [&hellip;]","og_url":"https:\/\/andely.us\/?succes-stories=how-we-helped-a-plastic-injection-plant-cut-90-of-its-energy-consumption","og_site_name":"Andely","og_image":[{"width":1300,"height":860,"url":"https:\/\/andely.us\/wp-content\/uploads\/2025\/10\/How-We-Helped-a-Plastic-Injection-Plant-Cut-90.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/andely.us\/?succes-stories=how-we-helped-a-plastic-injection-plant-cut-90-of-its-energy-consumption","url":"https:\/\/andely.us\/?succes-stories=how-we-helped-a-plastic-injection-plant-cut-90-of-its-energy-consumption","name":"How We Helped a Plastic Injection Plant Cut 90% of Its Energy Consumption - Andely","isPartOf":{"@id":"https:\/\/andely.us\/#website"},"primaryImageOfPage":{"@id":"https:\/\/andely.us\/?succes-stories=how-we-helped-a-plastic-injection-plant-cut-90-of-its-energy-consumption#primaryimage"},"image":{"@id":"https:\/\/andely.us\/?succes-stories=how-we-helped-a-plastic-injection-plant-cut-90-of-its-energy-consumption#primaryimage"},"thumbnailUrl":"https:\/\/andely.us\/wp-content\/uploads\/2025\/10\/How-We-Helped-a-Plastic-Injection-Plant-Cut-90.webp","datePublished":"2025-10-31T02:02:32+00:00","breadcrumb":{"@id":"https:\/\/andely.us\/?succes-stories=how-we-helped-a-plastic-injection-plant-cut-90-of-its-energy-consumption#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/andely.us\/?succes-stories=how-we-helped-a-plastic-injection-plant-cut-90-of-its-energy-consumption"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/andely.us\/?succes-stories=how-we-helped-a-plastic-injection-plant-cut-90-of-its-energy-consumption#primaryimage","url":"https:\/\/andely.us\/wp-content\/uploads\/2025\/10\/How-We-Helped-a-Plastic-Injection-Plant-Cut-90.webp","contentUrl":"https:\/\/andely.us\/wp-content\/uploads\/2025\/10\/How-We-Helped-a-Plastic-Injection-Plant-Cut-90.webp","width":1300,"height":860},{"@type":"BreadcrumbList","@id":"https:\/\/andely.us\/?succes-stories=how-we-helped-a-plastic-injection-plant-cut-90-of-its-energy-consumption#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/andely.us\/"},{"@type":"ListItem","position":2,"name":"How We Helped a Plastic Injection Plant Cut 90% of Its Energy Consumption"}]},{"@type":"WebSite","@id":"https:\/\/andely.us\/#website","url":"https:\/\/andely.us\/","name":"Andely","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/andely.us\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/andely.us\/index.php?rest_route=\/wp\/v2\/succes-stories\/2338","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/andely.us\/index.php?rest_route=\/wp\/v2\/succes-stories"}],"about":[{"href":"https:\/\/andely.us\/index.php?rest_route=\/wp\/v2\/types\/succes-stories"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/andely.us\/index.php?rest_route=\/wp\/v2\/media\/2282"}],"wp:attachment":[{"href":"https:\/\/andely.us\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2338"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}